PLC Lithium Batteries is offering by us to the clients. The PLC Lithium Batteries we offer is shock resistant and is known for its corrosion resistant. These batteries perform reliable operations and they have smooth functioning. Offered batteries are technically advanced and are user friendly in nature.
The storage area should be clean, cool (preferably not exceeding +30°C), dry and ventilated. Warning
Fire, explosion and burn hazard.
Do not recharge, short circuit, crush, disassemble, heat above 100°C (212°F), incinerate, or expose contents to water.
Do not solder directly to the cell (use tabbed cell versions instead).
Electrical characteristics
(typical values relative to cells stored for one year or less at +30°C max.) Nominal capacity 2.6 Ah (at 2 mA +20°C 2.0 V cut-off. The capacity restored by the cell varies according to current drain, temperature and cut-off)
Pulse capability: Typically up to 250 mA (250 mA/0.1 second pulses, drained every 2 mn at +20°C from undischarged cells with 10 µA base current, yield voltage readings above 3.0 V. The readings may vary according to the pulse characteristics, the temperature, and the cell’s previous history. Fitting the cell with a capacitor may be recommended in severe conditions. Consult Saft)
Maximum recommended continuous current 50 mA (Higher currents possible, consult Saft)
Operating temperature range -60°C/+85°C (Operation above ambient T may lead to reduced capacity and (-76°F/+185°F) lower voltage readings at the beginning of pulses. Consult Saft)